REETURKEY

THE GREATEST REE PROJECT EVER CONCEIVED

START FOR REETURKEY WEBSITE

Geophysical Operations

Geophysics – IP/Resistivity (IP/R)(Scanning underground by using electrical signals)

3.a.Magnetic Research

As a result of the data obtained from two licensed sites between November 2019 – January 2020, the next stage, magnetic measurements, was started with internationally competent, highly knowledgeable, and experienced Zeta Mühendislik and Mr. Tuğrul Toksöz. Except for a small portion of the licensed site that could not be completed due to winter conditions, diamond-shaped magnetic measurements were completed at 100-meter intervals in the northwest-southeast direction for the entire area. Measurement results and presentations are available in the attached file. As a result of magnetic measurements, 4 lines for IP/R studies were determined and the next stage was initiated.

3.b. IP/Resistivity (IP/R) Etude

IP/R was also conducted by Zeta Mühendislik and Mr. Toksöz. The measurements, which initially started with 4 profiles for the determined area, later reached a total of 12 profiles (34,650 meters) with intensified signals. With the IP/R carried out with 12 profiles in the Uşak mining area, chargeability and resistivity data were collected between the surface and approximately 300 meters underground. Chargeability and resistivity slices, floor maps, chargeability anomaly maps, and chargeability and resistivity model blocks were produced using the data obtained as a result of IP/R performed on the modified pole-dipole electrode array at measurement points determined at 50 meters intervals on each profile. In the mine site, there were strong and moderate charging anomalies, determined by the IP/R performed in the modified pole-dipole array. Here, 5 exploration drilling points were determined to detect resistivity discontinuities and/or some of the strong chargeability anomalies around the low resistivity zone. Documents and images related to IP/Resistivity (IP/R) findings are attached. As a result of the IP/R research, a 53.000.000 m3 anomaly cut by 10 lines laid in parallel at 200 meters intervals were detected and drilling points were determined on these lines. These lines are B-600, B-800, C-1000, C-1200, D-1800, respectively. Further research for the recharges on the A and B lines has been postponed for later investigation.

Geophysical Operations

Geophysical Operations Gallery

Click the button below to view the Chargeability Model Range and Resistivity Model 3D pdf.

If the pdf does not open in 3D, you can open it by downloading the adobe pdf plugin from the link below.

Click for 3D pdf view DOWNLOAD

Geophysical Operations

Magnetic Analysis

Address

Turkey

Contacts

cengiz@reeturkey.com

+90 533 385 16 97

Contact Us

Fill in the form to get in touch.

Send your message